HVAC

Heat pumps using R290: efficient, environmentally friendly and PFAS-free

Text WOLF Energiesystemen and Lieke BousemaImage WOLF Energiesystemen

Heat pumps using R290: efficient, environmentally friendly and PFAS-free

The natural refrigerant R290 (propane) is renowned for its thermodynamic properties, making it a popular choice for heating applications. As R290 heat pumps do not require the addition of PFAS, they are also efficient, environmentally friendly and safe, and comply with the F-gas Regulation. Maarten Ouwehand, Heating Team Leader at WOLF Energiesystemen, explains the benefits of R290.

“Alongside efficiency, increasing attention is being paid to the environmental properties of the refrigerant used when assessing heat pumps,” he says. “There are good reasons for this, as many synthetic refrigerants contain harmful poly- and perfluoroalkyl substances (PFAS).” PFAS are considered toxic and are therefore banned throughout Europe. “Because they are extremely persistent (‘forever’) chemicals, they accumulate in the environment and eventually in the human body. There, they can damage the liver and cause thyroid disorders, obesity, fertility problems and cancer.”

Natural and environmentally friendly

By contrast, natural refrigerant R290 is a truly ‘clean substance’, according to Ouwehand. “It is a naturally occurring hydrocarbon that is available in virtually unlimited quantities and has excellent cooling properties. R290 does not damage the ozone layer and has a very low Global Warming Potential (GWP) of 3, while offering significant thermodynamic benefits:

  • Flow temperatures of up to 70°C, even at low outdoor temperatures.
  • A high COP of 4.65 at A2/W35 in accordance with EN14511.
  • A high EER of 5.92 at A35/W18 in accordance with EN14511.

This last figure is particularly interesting when the heat pump is used for both heating and cooling.”

Maximum safety

The only drawback of R290 is its flammability. The refrigerant is therefore classified in safety group 3 under DIN EN 378 (Refrigerating systems and heat pumps: safety and environmental requirements). “In the WOLF CHA monobloc heat pump, safety is ensured by housing the entire refrigeration circuit in a hermetically sealed system in the outdoor unit. Heat is transferred to the building via water. This also means that no refrigeration handling certificate is required for installation. Any leaks of the refrigerant, which occurs naturally in the environment, pose no risk to the environment or to installers’ health. Installers do not need to work on the refrigeration circuit, which is filled at the factory. Precise installation specifications ensure maximum safety.”

The F-gas Regulation favours R290

Another point in R290’s favour is the F-gas Regulation, which has been in force since 1 January 2015. “Whereas most refrigerants previously used in heat pumps are now classified as climate-damaging, the F-gas Regulation explicitly exempts propane from the ban on refrigerants that damage the climate and deplete the ozone layer,” Ouwehand says. The aim of the F-gas Regulation is to drastically reduce the use of hydrofluorocarbon (HFC)-based refrigerants through a phased plan. The Regulation is intended to reduce the CO2 equivalent to 21% by 2030. It also bans the continued use of HFC refrigerants in certain applications. “Experts expect this gradual reduction in volumes (the F-gas phase-down), and the associated shortage of refrigerants with a high GWP, to lead to huge price rises and market disruption. Systems that require regular maintenance will be particularly affected by price increases.”

GWP as the key parameter

Since 2015, the so-called GWP value has been the key factor in refrigerant selection. “The GWP value defines the average warming effect of a chemical compound or refrigerant on the Earth’s atmosphere over a 100-year period, compared with the same quantity of carbon dioxide (CO2),” Ouwehand explains. “It therefore corresponds to the CO2 equivalent of a chemical. Refrigerant R290 has a GWP value of 3, and thus only a minimal greenhouse effect.” The ODP value, or ozone depletion potential, is another characteristic that describes the properties of a chemical compound. “The ODP value describes the relative ozone-depleting effect a substance can have. R11 (trichlorofluoromethane) is the reference substance, with an ODP value of 1. Values above 1 indicate greater ozone depletion, while values below 1 indicate less.” R290 has an ODP value of 0.

An excellent choice

The EU has recently introduced a ban on the use of F-gases in split air-conditioning systems and heat pumps, which will come into effect in 2035. “This decision reflects the trend towards phasing out refrigerants with a high GWP and wider adoption of those with a low GWP,” says Ouwehand. “Refrigerants with a higher GWP will become increasingly expensive to maintain as they become scarcer. This means that today’s lower-priced heat pumps using high-GWP refrigerants may incur high follow-on costs for maintenance and disposal. Choosing an R290 heat pump, on the other hand, means you can be confident there will be no additional costs due to a refrigerant shortage during the heat pump’s estimated service life.” In the medium term, he says, there is no significant alternative to natural refrigerants in terms of environmental performance, efficiency and availability. “R290 refrigerant continues to impress. It is safe and easy to monitor, inexpensive and efficient to use, making it an excellent choice.”

A business enquiry for WOLF Energiesystemen? Get in touch

Companies in this story